General | ||||
Material Status
|
|
|||
Search for UL Yellow Card
|
|
|||
Availability
|
|
|||
Filler / Reinforcement
|
|
|||
Uses
|
|
Physical |
Nominal Value
|
Unit
|
Test Method
|
Density / Specific Gravity
|
1.72
|
g/cm3
|
ASTM D792 |
Molding Shrinkage - Flow (3.20 mm)
|
0.20 to 0.50
|
%
|
ASTM D955 |
Water Absorption (24 hr, 23°C, 50% RH)
|
0.50
|
%
|
ASTM D570 |
Hardness |
Nominal Value
|
Unit
|
Test Method
|
Rockwell Hardness (R-Scale)
|
120
|
|
ASTM D785 |
Mechanical |
Nominal Value
|
Unit
|
Test Method
|
Tensile Strength 1 (Yield, 3.00 mm)
|
216
|
MPa
|
ASTM D638 |
Tensile Elongation 1 (Break, 3.00 mm)
|
2.5
|
%
|
ASTM D638 |
Flexural Modulus 2 (3.20 mm)
|
15700
|
MPa
|
ASTM D790 |
Flexural Strength 2 (3.20 mm)
|
343
|
MPa
|
ASTM D790 |
Impact |
Nominal Value
|
Unit
|
Test Method
|
Notched Izod Impact (23°C, 3.20 mm)
|
150
|
J/m
|
ASTM D256 |
Thermal |
Nominal Value
|
Unit
|
Test Method
|
Deflection Temperature Under Load (1.8 MPa, Unannealed)
|
210
|
°C
|
ASTM D648 |
Peak Melting Temperature
|
220
|
°C
|
ASTM D3418 |
CLTE - Flow
|
2.0E-5
|
cm/cm/°C
|
ASTM D696 |
Electrical |
Nominal Value
|
Unit
|
Test Method
|
Volume Resistivity (23°C)
|
1.0E+14
|
ohms·cm
|
ASTM D257 |
Dielectric Strength (23°C, 1.00 mm)
|
25
|
kV/mm
|
ASTM D149 |
Dielectric Constant (23°C, 1.00 GHz)
|
4.00
|
|
ASTM D150 |
Injection |
Nominal Value
|
Unit
|
|
Drying Temperature
|
80 to 100
|
°C
|
|
Drying Time
|
4.0 to 5.0
|
hr
|
|
Suggested Max Moisture
|
0.12
|
%
|
|
Rear Temperature
|
250 to 270
|
°C
|
|
Middle Temperature
|
260 to 285
|
°C
|
|
Front Temperature
|
260 to 290
|
°C
|
|
Nozzle Temperature
|
260 to 290
|
°C
|
|
Processing (Melt) Temp
|
260 to 290
|
°C
|
|
Mold Temperature
|
80 to 100
|
°C
|
|
Screw Speed
|
60 to 150
|
rpm
|